1. Introduction
- Lehmann J.
- Alves A.
- Dunn L.
- Shaw M.
- Kenny J.
- Keehan S.
- et al.
- Chelminski K.
- Bulski W.
- Lehmann J.
- Alves A.
- Dunn L.
- Shaw M.
- Kenny J.
- Keehan S.
- et al.
- Lechner W.
- Wesolowska P.
- Azangwe G.
- Arib M.
- Alvese V.
- Suming L.
- et al.
- Pasler M.
- Hernandez V.
- Jornet N.
- Clark C.H.
2. Beam output
Andreo P, Burns DT, Hohlfeld K, Huq MS, Kanai T, Laitano F et al. Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water: IAEA Proc Ser Stand Codes Pract Med Radiat Dosim IAEA – TRS 398 (ISBN 92-0-102200-X) 2000.
3. Advanced techniques
- Chelminski K.
- Bulski W.
- Lechner W.
- Wesolowska P.
- Azangwe G.
- Arib M.
- Alvese V.
- Suming L.
- et al.
4. Future directions
- Pasler M.
- Hernandez V.
- Jornet N.
- Clark C.H.
5. The role for ESTRO in dosimetry audit
6. Conflict of interest
References
- Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.Br J Radiol. 2015; 88: 1055
- Accuracy required and achievable in radiotherapy dosimetry: have modern technology and techniques changed our views?.J Phys Conf Ser. 2013; 444: 012006
- Design, development, and implementation of the Radiological Physics Center’s pelvis and thorax anthropomorphic quality assurance phantoms.Med Phys. 2007; 34: 2070
- The IAEA/WHO TLD postal programme for radiotherapy hospitals.Radiother Oncol. 2000; 54: 65-72
- Multicenter validation of IMRT pre-treatment verification: comparison of in-house and external audit.Radiother Oncol. 2014; 112: 381-388
- Multicenter audit of VMAT planning and pre-treatment verification.Radiother Oncol. 2017; 124: 302-310
- Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy.Phys Imag Radiat Oncol. 2018; https://doi.org/10.1016/j.phro.2018.03.006
- A multi-centre analysis of radiotherapy beam output measurement.Phys Imag Radiat Oncol. 2017; 4: 39-43
- Radiotherapy reference dose audit in the United Kingdom by the National Physical Laboratory: 20 years of consistency and improvements.Phys Imag Radiat Oncol. 2017; 3: 21-27
- An on-site dosimetry audit for high-energy electron beams.Phys Imag Radiat Oncol. 2018; 5: 44-51
- A multi-centre analytical study of small field output factor calculations in radiotherapy.Phys Imag Radiat Oncol. 2018; https://doi.org/10.1016/j.phro.2018.03.007
Clemente S, Masi L, Fiandra C, Cagni E, Villaggi E, Esposito M, et al. A multi-center output factors intercomparison to uncover systematic inaccuracies in small field dosimetry. Phys Imag Radiat Oncol 2018 (in press).
- A national dosimetry audit for stereotactic ablative radiotherapy in lung.Radiother Oncol. 2017; 122: 406-410
- A multi-centre dosimetry audit on advanced radiotherapy in lung as part of the isotoxic IMRT study.Phys Imag Radiat Oncol. 2017; 4: 17-21
- Lungtech, a phase II EORTC trial of SBRT for centrally located lung tumours – a clinical physics perspective.Radiat Oncol. 2016; 20: 7
- Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center’s anthropomorphic thorax phantom used for RTOG credentialing.Int J Radiat Oncol Biol Phys. 2013; 85: 95-100
- The role of dosimetry audit in lung SBRT multi-centre clinical trials.Phys Med. 2017; 44: 171-176
- Credentialing results from IMRT irradiations of an anthropomorphic head and neck phantom.Med Phys. 2013; 40: 022101
- The Swiss IMRT dosimetry intercomparison using a thorax phantom.Med Phys. 2010; 37: 4424
- A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry.Radiother Oncol. 2014; 113: 279-282
- A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy.Phys Imag Radiat Oncol. 2018; https://doi.org/10.1016/j.phro.2018.02.005
- The Radiological Physics Center’s standard dataset for small field size output factors.J Appl Clin Med Phys. 2012; 13: 3962
- Erratum: “The Radiological Physics Center’s standard dataset for small field size output factors”.J Appl Clin Med Phys. 2014; 15: 4757
- Dosimetry for audit and clinical trials: challenges and requirements.J Phys Conf Ser. 2013; 444: 012014
- Novel methodologies for dosimetry audits: adapting to advanced radiotherapy techniques.Phys Imag Radiat Oncol. 2018; https://doi.org/10.1016/j.phro.2018.03.002
- Evaluation of the water-equivalence of plastic materials in low- and high-energy clinical proton beams.Phys Med Biol. 2017; 62: 3883-3901
- Developing and characterizing MR/CT-visible materials used in QA phantoms for MRgRT systems.Med Phys. 2018; 45: 773-782
- Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit.Br J Radiol. 2017; 90: 1094
- Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification.Phys Med Biol. 2015; 60: 8741-8752
- A methodology for dosimetry audit of rotational radiotherapy using a commercial detector array.Radiother Oncol. 2013; 108: 78-85
- Auditing local methods for quality assurance in radiotherapy using the same set of predefined treatment plans.Phys Imag Radiat Oncol. 2018; 5: 19-25
- Institutional patient-specific IMRT QA does not predict unacceptable plan delivery.Int J Radiat Oncol Biol Phys. 2014; 90: 1195-1201
- Global harmonization of quality assurance naming conventions in radiation therapy clinical trials.Int J Radiat Oncol Biol Phys. 2014; 90: 1242-1249
- IMRT credentialing for prospective trials using institutional virtual phantoms: results of a joint European Organization for the Research and Treatment of Cancer and Radiological Physics Center project.Radiat Oncol. 2014; 9: 123
- Global availability of dosimetry audits in radiotherapy: the IAEA dosimetry audit networks database.Phys Imag Radiat Oncol. 2018; 5: 1-4
- A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions.Radiother Oncol. 2007; 84: 67-74
- Institute of Physical Sciences in Medicine (IPSM) 1990 code of practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration service.Phys Med Biol. 1990; 35: 1355-1360
Andreo P, Burns DT, Hohlfeld K, Huq MS, Kanai T, Laitano F et al. Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water: IAEA Proc Ser Stand Codes Pract Med Radiat Dosim IAEA – TRS 398 (ISBN 92-0-102200-X) 2000.
Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R et al. Protocol for clinical reference dosimetry of high-energy photon and electron beams. AAPM TG51 1999:1847–70.
Aalbers AHL, Hoornaert M-T, Minken A, Palmans H, Pieksma MWH, Prez LA de, et al. NCS report 18 – Code of Practice for the absorbed 403 Dose determination in high energy photon and electron beams, 2008.
IAEA. Dosimetry of small static fields used in external beam radiotherapy: an international code of practice for reference and relative dose determination. TRS 483 2017.
- Technical report: reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data.Med Phys. 2016; 43: 2374-2386
- Dose calculation algorithm accuracy for small fields in non-homogeneous media: the lung SBRT case.Phys Med. 2017; 44: 157-162
- National audit of a system for rectal contact brachytherapy.Phys Imag Radiat Oncol. 2017; 1: 1-5
- Remote dosimetric auditing for intensity modulated radiotherapy: a pilot study.Phys Imag Radiat Oncol. 2017; 4: 26-31
- Comparison of complexity metrics for multi-institutional evaluations of treatment plans in radiotherapy.Phys Imag Radiat Oncol. 2018; 5: 37-43
Article info
Publication history
Identification
Copyright
User license
Creative Commons Attribution – NonCommercial – NoDerivs (CC BY-NC-ND 4.0) |
Permitted
For non-commercial purposes:
- Read, print & download
- Redistribute or republish the final article
- Text & data mine
- Translate the article (private use only, not for distribution)
- Reuse portions or extracts from the article in other works
Not Permitted
- Sell or re-use for commercial purposes
- Distribute translations or adaptations of the article
Elsevier's open access license policy